Price Excludes VAT and Shipping
The Hyco Speedflow 10 Litre and 15 Litre Unvented Water Heaters are ideal for use in cloakrooms and kitchens in offices, shops, student accommodation and domestic premises which have been extended and there is no central hot water system nearby. One unit located under the kitchen sink is often used to supply hot water for light dish washing in the kitchen sink and hand washing in the cloakroom basin.
Features
• Supplies hot water for up to 3 basins
- 1 – 2 basins: 10L
- 2 – 3 basins: 15L
• Can be used with regular taps including mixers
• Mains pressure flow rates
• 2.0 kW element as standard
• Neon element on indicator
• Glass lined steel tank as standard
• External temperature control with frost protection setting
• Accessories may be needed to comply with the Water Regulations. Pressure reducing valve required for pressures above 4.2 bar and expansion vessel and check valve required if cold water draw off nearby.
• Not suitable for hair wash basins in hairdressing salons
Hyco Speedflow 10 Litre and 15 Litre Unvented Water Heaters SF10K and SF15K
Technical Specifications
Outer Casing: Easy clean, high impact plastic
Heating Element: Stainless steel flange type
Thermostat:
- Bulb type adj. to 75°C
- E setting approx. 50°C
Water Tank: Glass lined steel
Anode: Replaceable grey magnesium
Insulation: High density polyurethane foam
Safety:
- Overheat temperature protection (manual reset).
- Supplied pressure relief valve must be fitted in every case (set at 6 bar).
- Frost protection if power on.
- Optional thermostatic mixing valve to maintain hot water supplied to user at constant, safe temperature.
IP Rating: IPX4
Installation:
- Site above or below the sink, but inlet and outlet must be at the top.
- Floor standing or wall mounted.
- Access to the thermal cut-out and element is located at the base of unit.
- Minimum water pressure 0.5 bar.
- Maximum water pressure 4.2 bar.
Water connection:
- Inlet/ Outlet 2 x 1/2" BSP male (100mm apart centre to centre).
- Fittings required (not supplied): 2 x 15mm compression to 1/2" BSP female adapter.
Electrical Connection:
- Installation must comply with current IEE regulations.
- The product should be connected to the fixed wiring of the property via a double pole fused spur with a minimum break capacity of 13 amps.
- Cable pre-wired (1.5m).
Approvals: CE, UKCA, WRAS